Operation CHARM: Car repair manuals for everyone.

Test V: The Individual Reversing Lamp Is Inoperative

PINPOINT TEST V: THE INDIVIDUAL REVERSING LAMP IS INOPERATIVE


V1:






Normal Operation
When the transaxle is placed in REVERSE (R), voltage is supplied to the reversing lamps through circuit CBP12 (GN/WH). Ground to the reversing lamps is provided through circuit GD171 (BK/GY).

Possible Causes
- Circuit CBP12 (GN/WH) open
- Circuit GD171 (BK/GY) open