Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Circuit Check




CAN Communication Circuit Check

1. CONNECTOR INSPECTION

1 Turn the ignition switch OFF.
2 Disconnect the battery cable from the negative terminal.
3 Disconnect all the unit connectors on CAN communication system.
4 Check terminals and connectors for damage, bend and loose connection.

Is the inspection result normal?
YES
GO TO 2.
NO
Repair the terminal and connector.

2. CHECK HARNESS CONTINUITY (SHORT CIRCUIT)

Check the continuity between the data link connector terminals.






Is the inspection result normal?
YES
GO TO 3.
NO
Check the harness and repair the root cause.

3. CHECK HARNESS CONTINUITY (SHORT CIRCUIT)

Check the continuity between the data link connector and the ground.






Is the inspection result normal?
YES
GO TO 4.
NO
Check the harness and repair the root cause.

4. CHECK ECM AND IPDM E/R TERMINATION CIRCUIT

1 Remove the ECM and the IPDM E/R.
2 Check the resistance between the ECM terminals.











3 Check the resistance between the IPDM E/R terminals.






Is the measurement value within the specification?
YES
GO TO 5.
NO
Replace the ECM and/or the IPDM E/R.

5. CHECK SYMPTOM

Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.

Inspection result
Reproduced
GO TO 6.
Non-reproduced
Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.

6. CHECK UNIT REPRODUCTION

Perform the reproduction test as per the following procedure for each unit.
1 Turn the ignition switch OFF.
2 Disconnect the battery cable from the negative terminal.
3 Disconnect one of the unit connectors of CAN communication system.

NOTE:
ECM and IPDM E/R have a termination circuit. Check other units first.

4 Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.

NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.

Inspection result
Reproduced
Connect the connector. Check other units as per the above procedure.
Non-reproduced
Replace the unit whose connector was disconnected.