Heating and Air Conditioning: Specifications
| Discharge hose to compressor | 9.8 Newton Meter (Nm) |
| Discharge hose to condenser | 9.8 Newton Meter (Nm) |
| Condenser line to condenser | 9.8 Newton Meter (Nm) |
| Consenser line to receiver/drier | 13 Newton Meter (Nm) |
| Receiver line to receiver/drier | 13 Newton Meter (Nm) |
| Receiver line to evaporator | 13 Newton Meter (Nm) |
| Suction line to evaporator | 31 Newton Meter (Nm) |
| Suction hose to suction line | 31 Newton Meter (Nm) |
| Suction hose to compressor | 9.8 Newton Meter (Nm) |
| Compressor to compressor bracket | 22 Newton Meter (Nm) |
| Compressor backet to cylinder block | 49 Newton Meter (Nm) |