Secondary Injection Combination Valve, Checking For Function and Leaks






Secondary Injection Combination Valve, Checking for Function and Leaks

Procedure

Vacuum lines and hose connections free of leaks.

Vacuum lines not plugged.

- Disconnect the secondary air hose - arrow - and connect the assisting hose into the hose leading to the secondary air combination valve.





- Blow lightly into assisting hose by mouth, do not use compressed air.

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Blow more strongly into assisting hose by mouth, do not use compressed air.

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

- If the switch point cannot be detected, replace secondary air injection (AIR) combination valve. Refer to => [ Secondary Air Injection (AIR) Combination Valve ] Secondary Air Injection (AIR) Combination Valve.