Scan Tool Data Definitions
Scan Tool Data Definitions
8-Digit GM Part Number
- The scan tool displays the part number of the module.
Battery Voltage
- The scan tool displays 0-16 volts. The level of battery voltage at the module.
Calibration ID
- The scan tool displays a 4-digit number. This number designates the calibration or program level used in the PROM.
Current
- The scan tool displays 0-127.5 amps. The current measured during adjustable pedals or seat operation.
Hardware Level
- The scan tool displays a 4 digit number representing the level of hardware incorporated into the module.
Julian Date of Build
- The scan tool displays a 3-digit number. This number is the day of the year that the module was built.
PROM ID
- The scan tool displays a 4-digit number. This is the identification number of the PROM that is incorporated into the module.
Pedals Position Sensor
- The scan tool displays 0-5.0 volts or 0-255 A/D. The sensor potentiometer provides an analog voltage which varies directly with the adjustable pedals position. High scan tool values (volts or A/D) indicate that the pedals are in the froward position and low values indicate that the pedals are in the rearward position.
Pedals Forward - Input
- The scan tool displays Inactive/Active. When the adjustable pedals forward switch is activated, the scan tool will momentarily display switch input to the driver position module as Active.
Pedals Forward - Output
- The scan tool displays Inactive/Active. When the adjustable pedals forward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the driver position module is commanding the adjustable pedals motor in the forward direction.
Pedals Rearward - Input
- The scan tool displays Inactive/Active. When the adjustable pedals rearward switch is activated, the scan tool will momentarily display the switch input to the driver position module as Active.
Pedals Rearward - Output
- The scan tool displays Inactive/Active. When the adjustable pedals rearward switch is activated or when a memory recall occurs, the scan tool will momentarily display Active while the output from the driver position module is commanding the adjustable pedals motor in the rearward direction.
Software Level
- The scan tool displays the 4-digit number of the software incorporated into the module.
Year Module Built
- The scan tool displays a 4-digit number. This number represents the year the module was built.