Control Switch Test
Measure the resistance between the terminals when each of the SET, RESUME and CANCEL switches is pressed.
If the values measured at this time correspond to those shown below, then there is no problem.
Switch Position Resistance Between Terminals Switch OFF
No continuity
CANCEL switch ON
Approx. 0 ohms
RESUME switch ON
Approx. 820 ohms
SET switch ON
Approx. 2,700 ohms