Operation CHARM: Car repair manuals for everyone.

No Door Locks Operate With Transmitter





ALL DOORS DO NOT LOCK WITH THE TRANSMITTER

(1) Using a voltmeter, check Pin 6 of the RKE module black connector for a voltage pulse. Press the lock button on the transmitter. Wait for quick voltage pulse. It may be necessary to press the transmitter several times. The voltage pulse only appears for milliseconds.

(2) If no voltage pulse is measured, replace remote keyless entry module. If a voltage is measured, repair the harness to the lock relay.