Static Timing
SETTING INJECTION STATIC TIMING1. Remove fast idle bracket and solenoid from injection pump.
Injection Pump Mounting Wrench T83T-9000-B:
2. Break torque (keeping nuts snug) on three nuts attaching injection pump to pump mounting adapter using Injection Pump Mounting Wrench T83T-9000-B.
Injection Pump Rotating Tool T83T-9000-C:
3. Install Injection Pump Rotating Tool T83T-9000-C on front of pump and rotate injection pump to align timing mark on injection pump mounting flange with timing mark on pump mounting adapter, to within ± 0.75 mm (0.030 inches).
Injection Pump Timing Marks:
4. Remove rotating tool and tighten nuts to 35 Nm (26 ft lb). Visually check timing to verify that timing marks are aligned as shown in the Injection Pump Timing Marks image. Install fast idle bracket and solenoid and torque bolts.