Recovery of Contaminated A/C Systems
Recovery of Contaminated A/C Systems1. Repeat the refrigerant identification. Refrigerant Identification and Analysis
2. Advise the customer of the contaminated A/C system and any additional costs to service the system.
NOTE: The customer may want to return to the facility responsible for the last A/C system service.
3. Recover the contaminated refrigerant, using suitable recovery only equipment designed for the recovery of contaminated refrigerant.
CAUTION: This equipment MUST only be used to recover contaminated refrigerant to prevent the spread of contaminated refrigerant to other vehicles. As an alternative, contact an A/C service facility in your area that is equipped to handle contaminated A/C systems.
4. Determine the cause of the failure.
5. Determine which parts will need to be replaced.
6. Flush the heat exchangers.
NOTE: If the vehicle is equipped with an auxiliary A/C and heater system, the evaporator core in the unit must also be flushed to prevent system recontamination.
7. Install a new suction accumulator/drier.
8. Add the necessary amount of refrigerant oil.
9. Evacuate the A/C system for 45 minutes.
10. Recharge the A/C system.
11. Dispose of the contaminated refrigerant in accordance with all federal, state, and local laws and regulations.
NOTE: Contact your current hazardous waste disposal company to determine if it is capable of disposing contaminated refrigerant.