Hose/Line HVAC: Service and Repair
REMOVAL
1. Perform the Refrigerant Discharging and Recovery Procedure. Refer to: Heating and Air Conditioning, Service and Repair, Refrigerant Discharging and Recovery Procedure, Refrigerant Discharging and Recovery procedure
2. Unlatch the air breather.
3. Disconnect the mass air flow sensor electrical connector.
4. Remove the air cleaner outlet tube.
1. Loosen the clamp.
2. Disconnect the the crankcase ventilation tube.
3. Remove the air cleaner outlet tube.
5. Remove the nut and separate the line from the condenser.
6. Disconnect the line.
7. Remove the clamp.
8. Remove the line.
INSTALLATION
1. To install, reverse the removal procedure.
2. Perform Evacuation and Charging Procedure. Refer to: Heating and Air Conditioning, Service and Repair, Evacuation and Charging Procedure, Evacuation and Charging Procedure