Test S

PINPOINT TEST S: THE AUXILIARY BLOWER MOTOR DOES NOT OPERATE CORRECTLY USING THE FRONT AUXILIARY CLIMATE CONTROLS


Test S1:






Test S1-S2:






Test S3-S4:






Test S5-S6:






Normal Operation
Under normal operation, the blower motor is provided a ground from the resistor through circuit 515 (OG/RD). The resistor gets a ground from the front auxiliary blower switch, depending on selected speed, through circuit 261 (OG/BK), 269 (LB/OG) or circuit 260 (RD/OG).

Possible Causes
- An open, short to ground or together in circuits 515 (OG/RD), 261 (OG/BK), 269 (LB/OG) or 260 (RD/OG).
- Auxiliary blower motor resistor.
- Front auxiliary climate control assembly.