Test V: No Medium Speed Controller Area Network (Ms-Can) Communication, All Modules Are Not Responding

PINPOINT TEST V: NO MEDIUM SPEED CONTROLLER AREA NETWORK (MS-CAN) COMMUNICATION, ALL MODULES ARE NOT RESPONDING


V1-V2:






V3-V4:






V5-V6:






V7-V9:






V9-V11:






V11-V13:






V13-V16:






Normal Operation
The MS-CAN uses an unshielded twisted pair cable, circuits 1847 (WH/OG) and 1848 (PK/OG). The smart junction box (SJB), the audio control protocol (ACP) module and the instrument cluster communicate with the scan tool using the MS-CAN network.

Possible Causes
- Circuit 1847 (WH/OG) open, short to ground or voltage (MS-CAN +)
- Circuit 1848 (PK/OG) open, short to ground or voltage (MS-CAN -)
- Circuit 1847 (WH/OG) (MS-CAN +) and circuit 1848 (PK/OG) (MS-CAN -) shorted together
- SJB
- ACP module
- Instrument cluster