Test J: The Panic Feature Is Inoperative
PINPOINT TEST J: THE PANIC FEATURE IS INOPERATIVEJ1-J4:
J5:
Normal Operation The panic function is accomplished by the smart junction box (SJB) receiving a command message from the remote keyless entry (RKE) transmitter through the SJB external antenna. The SJB processes the command and sends a signal activating the horn and parking lamps.
Possible Causes -
RKE transmitter
-
SJB