Pinpoint Test Q: The Anti-Theft Indicator Is Never/Always On
Instrumentation, Message Center and Warning Chimes
Pinpoint Tests
Pinpoint Test Q: The Anti-Theft Indicator Is Never/Always On
Normal Operation
The Instrument Cluster (IC) interacts with the PCM and controls the Passive Anti-Theft System (PATS) function based upon the status of the PATS.
The anti-theft indicator proves out for 3 seconds when the key is turned to the ON or START position. If there is a PATS concern, the anti-theft indicator either flashes rapidly or glows steadily (for more than 3 seconds) when the key is turned to the ON or the START position. The PATS also flashes the anti-theft indicator every 2 seconds at key off to act as a visual theft deterrent.
This pinpoint test is intended to diagnose the following:
- PATS concern
- IC
PINPOINT TEST Q: THE ANTI-THEFT INDICATOR IS NEVER/ALWAYS ON
-------------------------------------------------
Q1 CARRY OUT THE IC ANTI-THEFT INDICATOR ACTIVE COMMAND USING THE SCAN TOOL
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: IC DataLogger.
- Select the IC anti-theft indicator (THEFT_LMP) active command. Command the anti-theft indicator on and off while observing the anti-theft indicator.
- Does the anti-theft indicator illuminate when commanded on, and turn off when commanded off?
Yes
GO to Q2.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------
Q2 RETRIEVE THE RECORDED DTCs FROM THE CONTINUOUS IC SELF-TEST
- Check for recorded IC DTCs from the continuous self-test.
- Are any PATS related DTCs recorded?
Yes
REFER to Antitheft and Alarm Systems.
No
INSTALL a new IC. REFER to Instrument Cluster (IC) Instrument Cluster (IC). TEST the system for normal operation.
-------------------------------------------------