Ignition 1 ON
(Yes/No)The Ignition 1 On parameter indicates when the
VCM is detecting Ignition voltage. The normal Ignition voltage is approximately
13.8 volts, but may vary between
11-16 volts. The VCM monitors the Ignition voltage to compensate for low voltage operation of the injectors and to increase the dwell time of the
ignition coil.