Condenser HVAC: Service and Repair
Condenser Replacement
REMOVAL PROCEDURE
1. Remove the air cleaner.
2. Discharge and recover the refrigerant from the system. Refer to Refrigerant Recovery and Recharging.
3. Remove the grille.
4. Remove the compressor and condenser hose assembly.
5. Remove the evaporator tube from the condenser.
6. Remove the bolts that retain the condenser to the radiator.
7. Remove the condenser.
INSTALLATION PROCEDURE
1. Install the condenser.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the bolts that retain the condenser to the radiator.
Tighten
Tighten the bolts that retain the condenser to the radiator to 6 N.m (53 lb in).
3. Install the evaporator tube to the condenser.
4. Install the compressor and condenser hose assembly.
5. Install the grille.
6. Evacuate and charge the system. Refer to Refrigerant Recovery and Recharging.
7. Ensure that no leaks exist in the system.
8. Install the air cleaner.