Low-Reverse Brake End Play Adjustment
LOW-REVERSE BRAKE END PLAY ADJUSTMENTReverse the transmission and install a dial gauge. Move the special tool up and down to measure the end play.
Standard value: 1.35 -1 .81 mm
Select a pressure plate whose thickness is within the following value. [A (moving amount) + thickness of the special tool - 1.81] to [A (moving amount) + thickness of the special tool - 1.35]. (Refer to the "Snap ring and spacer for adjustment").