Mode Door Actuator - Installation







INSTALLATION






NOTE: LHD model shown. RHD model similar.

1. Position the mode door actuator (2) onto the bracket (4) located on the right side of the HVAC air distribution housing. If necessary, rotate the actuator slightly to align the splines on the actuator output shaft with those in the mode air door linkage.
2. Install the three screws (1) that secure the mode door actuator to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
3. Connect the wire harness connector (3) to the mode door actuator.
4. Install the floor distribution duct onto the right side of the air distribution housing Floor Distribution Duct - Installation.
5. On LHD models, install the glove box bin Instrument Panel Glove Box - Installation.
6. On LHD models, install the silencer panel and two push-pins.
7. Reconnect the negative battery cable.
8. Initiate the Actuator Calibration function using a scan tool