Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Inspection

INSPECT MASS AIR FLOW METER




a. Output voltage inspection.
1. Apply battery voltage across terminals 3 (+B) and 4 (E2G).
2. Connect the positive (+) tester prove to terminal 5 (VG), and negative (-) tester prove to terminal 4 (E2G).
3. Blow air into the MAP meter, and check if the voltage fluctuates.

b. Resistance inspection.
1. Using an Ohmmeter, measure resistance between the terminals 2 (THA) and 1 (E2).

Resistance:
12.5 - 16.9 Ohm at -20 °C (-4 °F)
2.19 - 2.67 Ohm at 20 °C (68 °F)
0.50 - 0.68 Ohm at 60 °C (140 °F)