No.7 DRIVER AND PASSENGER DOOR GLASSES OPERATE ACCIDENTALLY [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]


id090361995200

7

Driver and passenger door glasses operate accidentally

POSSIBLE CAUSE
•  Transmitter malfunction
•  Request switch malfunction
•  Open or short circuit in wiring harness between request switch (each door) and keyless control module.
•  Power window main switch malfunction
•  Power window subswitch (passenger side) malfunction
•  Open or short circuit in wiring harness between power window main switch and power window subswitch (passenger side)
•  BCM malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
•  Inspect if malfunction is in operating by transmitter
Yes
Inspect the transmitter.
No
With keyless entry system
•  Go to Step 3.
With advanced keyless system
•  Go to the next step.
2
•  Inspect if malfunction is in operating by request switch
Yes
Inspect the following parts and repair or replace.
•  Wiring harness between request switch and keyless control module
No
Go to the next step.
3
•  Inspect if malfunction is in operating power window main switch
Yes
Inspect power window main switch
No
Go to the next step.
4
•  Inspect if malfunction is in without operating Step1 to 3
Yes
Inspect the following parts and repair or replace
•  Power window subswitch (passenger side)
•  Wiring harness between power window subswitch (passenger side) and power window main switch
No
Reinspect for malfunction recurrence.If the malfunction is not corrected, repeat the procedure from Step 1.