5 |
ABS warning light stays on 4 s or more when the ignition switch to the ON position. |
[TROUBLESHOOTING HINTS] • ABS HU/CM detects ABS system malfunction. |
Diagnostic procedure
STEP
|
INSPECTION
|
ACTION
|
|
---|---|---|---|
1
|
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY AND SHORTS
• Perform the DTC inspection.
• Is an error message displayed regarding communication between the ABS HU/CM and the M-MDS?
|
Yes
|
If a communication error message is displayed even after inspecting according to procedures displayed in the M-MDS, go to Step 4.
|
No
|
Go to the next step.
|
||
2
|
INSPECT FOR DTCs IN ABS HU/CM
• Have DTCs been stored in memory?
|
Yes
|
Perform the applicable DTC inspection.
(See DTC Table.)
|
No
|
Go to the next step.
|
||
3
|
INSPECT WARNING LIGHT OPERATION
• Turn on the all warning light on instrument cluster using the instrument cluster input/output check code26.
• Does the warning light illuminate?
|
Yes
|
Replace the ABS HU/CM (open circuit or short to ground in ABS HU/CM).
|
No
|
Replace the instrument cluster.
|
||
*4 |
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY
Disconnect the ABS HU/CM connector.
• Is there continuity between connector terminal Z, Y and DLC-2?
|
Yes
|
Go to the next step.
|
No
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
||
*5 |
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO B+
• Is the voltage approx. 12V at connector terminal Z, Y?
|
Yes
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
No
|
Go to the next step.
|
||
*6 |
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO GROUND
• Is there continuity between connector terminal Z, Y and ground?
|
Yes
|
Repair the wiring harness between the ABS HU/CM and DLC-2.
|
No
|
Replace the ABS HU/CM (communication circuit malfunction in ABS HU/CM).
|
||
|
• When performing an asterisked (*) troubleshooting inspection, slightly shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, verify that the connectors, terminals and wiring harness are connected correctly and undamaged.