NO.5 ABS WARNING LIGHT STAYS ON 4 S OR MORE WHEN IGNITION SWITCH TURNED TO ON POSITION


id040300810200

5

ABS warning light stays on 4 s or more when the ignition switch to the ON position.

[TROUBLESHOOTING HINTS]

• ABS HU/CM detects ABS system malfunction.

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY AND SHORTS
• Perform the DTC inspection.
• Is an error message displayed regarding communication between the ABS HU/CM and the M-MDS?
Yes
If a communication error message is displayed even after inspecting according to procedures displayed in the M-MDS, go to Step 4.
No
Go to the next step.
2
INSPECT FOR DTCs IN ABS HU/CM
• Have DTCs been stored in memory?
Yes
Perform the applicable DTC inspection.
(See DTC Table.)
No
Go to the next step.
3
INSPECT WARNING LIGHT OPERATION
• Turn on the all warning light on instrument cluster using the instrument cluster input/output check code26.
• Does the warning light illuminate?
Yes
Replace the ABS HU/CM (open circuit or short to ground in ABS HU/CM).
No
Replace the instrument cluster.

*4

INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR CONTINUITY

Disconnect the ABS HU/CM connector.
• Is there continuity between connector terminal Z, Y and DLC-2?
Yes
Go to the next step.
No
Repair the wiring harness between the ABS HU/CM and DLC-2.

*5

INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO B+

• Is the voltage approx. 12V at connector terminal Z, Y?
Yes
Repair the wiring harness between the ABS HU/CM and DLC-2.
No
Go to the next step.

*6

INSPECT WIRING HARNESS BETWEEN ABS HU/CM AND DLC-2 FOR SHORT TO GROUND

• Is there continuity between connector terminal Z, Y and ground?
Yes
Repair the wiring harness between the ABS HU/CM and DLC-2.
No
Replace the ABS HU/CM (communication circuit malfunction in ABS HU/CM).

• When performing an asterisked (*) troubleshooting inspection, slightly shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, verify that the connectors, terminals and wiring harness are connected correctly and undamaged.