NO. 3 POWER RETRACTABLE HARDTOP DOES NOT START TO OPEN [POWER RETRACTABLE HARDTOP]
id0903j2851200
3
|
Power retractable hardtop does not to start open
|
DESCRIPTION
|
• Power retractable hardtop does not start to open when the power retractable hardtop (open) switch is pressed.
|
POSSIBLE CAUSE
|
• Power retractable hardtop control module cannot detect the power retractable hardtop permission condition signal.
• Power retractable hardtop control module cannot detect the proper power retractable hardtop switch signal.
• Power retractable hardtop control module detect an improper top lock status.
• Power retractable hardtop control module cannot detect proper deck panel and roof positions.
• Power retractable hardtop link mechanics malfunction.
• Power retractable hardtop control module detects a system malfunction.
|
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN OPERATION PERMISSION CONDITION SIGNAL OR ELSEWHERE
• Connect the M-MDS to the DLC-2.
• Monitor the following PIDs.
(See PCM INSPECTION [L8, LF].)
PCM
TCM (AT)
Power Retractable Hardtop Control Module
• Are these monitor values normal?
|
Yes
|
Go to the next step.
|
No
|
Inspect and repair the suspected signal related wiring harness and component.
|
||
2*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER RETRACTABLE HARDTOP (CLOSE) SWITCH SIGNAL OR ELSEWHERE
• Monitor the power retractable hardtop control module PID SW_CL (power retractable hardtop (close) switch) using the M-MDS without the power retractable hardtop (close) switch pressed.
• Is the monitor value OFF?
|
Yes
|
Go to Step 4.
|
No
|
Go to the next step.
|
||
3
|
INSPECT POWER RETRACTABLE HARDTOP (CLOSE) SWITCH
• Turn the ignition switch to the LOCK position.
• Remove the power retractable hardtop switch.
• Measure the resistance between power retractable hardtop switch component side connector terminals A and F without the power retractable hardtop (close) switch pressed.
• Is the resistance 2.1—2.3 kilohms?
|
Yes
|
Replace the power retractable hardtop switch.
|
No
|
Inspect and repair the wiring harness between power retractable hardtop control module terminal 1H and power retractable hardtop switch terminal F at wiring harness side connectors.
|
||
4
|
VERIFY THAT POWER RETRACTABLE HARDTOP INDICATOR LIGHT ILLUMINATION
• Turn the ignition switch to the ON position.
• Verify the power retractable hardtop indicator light status.
• Does the power retractable hardtop indicator light flash or illuminate?
|
Yes
|
If the indicator light is flashing:
Go to the next step.
If the indicator light is illuminated:
Go to Step 6.
|
No
|
Go to Step 9.
|
||
5
|
VERIFY THAT PRESENT MALFUNCTION DTC IS STORED
• Connect the M-MDS to DLC-2.
• Retrieve the DTC for the power retractable hardtop control module.
• Is there any present malfunction DTC?
|
Yes
|
Go to the appropriate DTC inspection.
|
No
|
Go to symptom troubleshooting “No.2 POWER RETRACTABLE HARDTOP INDICATOR LIGHT IS FLASHING” procedure.
|
||
6*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN TOP LOCK SWITCH OR ELSEWHERE
• Monitor the power retractable hardtop control module PID SW_STRIKER using the M-MDS while the top lock switch is released.
• Is the monitor value off?
|
Yes
|
Go to Step 8.
|
No
|
Go to the next step.
|
||
7
|
INSPECT TOP LOCK SWITCH
• Inspect the top lock switch.
(See TOP LOCK SWITCH INSPECTION.)
• Is the top lock switch normal?
|
Yes
|
Inspect and repair for an open or short circuit between the top lock switch and power retractable hardtop control module.
|
No
|
Replace the striker switch.
|
||
8*
|
INSPECT POWER RETRACTABLE HARDTOP LIMIT SWITCH AND DECK PANEL LIMIT SWITCH
• Monitor the power retractable hardtop control module PID RHT_OP, RHT_CL, DECK_OP and DECK_CL using the M-MDS.
• Do the monitoring values indicate the roof and deck panel positions properly?
|
Yes
|
Verify that the malfunction symptom appears without the roof and deck panel in the fully open position.
If the same symptom appears, replace the power retractable hardtop control module.
|
No
|
Inspect and repair suspected position sensor.
|
||
9*
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER RETRACTABLE HARDTOP (OPEN) SWITCH SIGNAL OR ELSEWHERE
• Monitor the power retractable hardtop control module PID SW_OP using the M-MDS while the power retractable hardtop (open) switch is pressed.
• Is the monitor value on?
|
Yes
|
Go to Step 10.
|
No
|
Go to the next step.
|
||
10
|
INSPECT POWER RETRACTABLE HARDTOP (OPEN) SWITCH
• Remove the power retractable hardtop switch.
• Measure the resistance between power retractable hardtop switch connector (component side) terminal A and F while the power retractable hardtop (open) switch is pressed.
• Is the resistance 0.95—1.05 kilohms?
|
Yes
|
Inspect and repair the wiring harness between power retractable hardtop control module terminal 1H and power retractable hardtop switch terminal F at the wiring harness side connectors.
|
No
|
Replace the power retractable hardtop switch.
|
||
11
|
INSPECT POWER RETRACTABLE HARDTOP LINK MECHANICS
• Inspect the roof and deck panel link mechanics.
• Is there any restriction or hesitation with roof and deck panel operation?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Replace the power retractable hardtop control module.
|