NO. 5 BRAKE SYSTEM WARNING LIGHT ILLUMINATES[INSTRUMENT CLUSTER]


id0903d5807800

5

Brake system warning light illuminates

POSSIBLE CAUSE
•  ABS HU/CM or DSC HU/CM malfunction
•  Brake fluid level sensor malfunction
•  Parking brake switch malfunction
•  Instrument cluster malfunction
•  Connector or pin malfunction
•  Short circuit in wiring harness between CAN-L, CAN-H and GND
•  Open circuit in CAN wiring harness (CAN-L, CAN-H)
•  CAN wiring harness (CAN-L, CAN-H) short each other

Diagnostic procedure

STEP

INSPECTION

ACTION

1
•  Start the engine.
•  Release the parking brake.
•  Does the brake system warning light turn off?
Yes
Troubleshooting completed.
No
Go to the next step.
2
•  Inspect the DTC for the ABS ON-BOARD DIAGNOSTIC SYSTEM.
•  Has DTC been recorded in memory?
Yes
Go to the applicable DTC troubleshooting procedure.
No
Go to the next step.
3
•  Does the brake fluid need replenishment?
Yes
Add brake fluid.
No
Go to the next step.
4
•  Inspect the brake fluid level sensor, parking brake switch or connectors.
•  Is there any malfunction?
Yes
Repair or replace malfunctioning part.
No
Go to the next step.
5
•  Start the instrument cluster input/output check mode.
•  Does the brake system warning light turn off with a check code other than 26?
Yes
Inspect the ABS HU/CM, DSC HU/CM, brake fluid level sensor, parking brake switch or connectors.
No
Replace the instrument cluster.
6
•  Disconnect the negative battery cable.
•  Measure the resistance between the DLC-2 terminals F and E.
•  Is the resistance 54—66 ohms?
Yes
Go to the next step.
No
Go to Step 7.
7
•  Disconnect the negative battery cable.
•  Inspect the DLC-2 terminals F and E for short to power supply or GND.
•  Is there any malfunction?
Yes
Inspect the wiring harness and CAN system-related module.
Repair or replace the malfunctioning part.
No
Replace the instrument cluster.
8
•  Turn the ignition switch off.
•  Inspect the instrument cluster connector terminals for poor connection (such as damaged/pulled-out pins, and corrosion).
•  Are the terminals normal?
Yes
Go to the next step.
No
Repair or replace the terminal.
9
•  Disconnect the negative battery cable.
•  Measure the resistance between the instrument cluster connector terminals 1I and 1K.
•  Is the resistance 114—126 ohms?
Yes
Inspect the wiring harness and CAN system-related module.
Repair or replace the malfunctioning part.
No
Replace the instrument cluster.