ON-BOARD DIAGNOSTIC SYSTEM DTC TABLE [FW6A-EL]


id050225290200

×: Applicable
—: Not applicable

DTC No.

MIL

AT warning light

Description

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

P0218:00
Illuminate
Illuminate
Automatic transaxle protection control
×
1
C
×
P0500:00
Illuminate
Vehicle speed signal circuit malfunction
×
1
C
×
P0666:00
Illuminate
Illuminate
ECU internal temperature sensor circuit(s) malfunction
×
2
C
×
P0667:00
Illuminate
Illuminate
ECU internal temperature sensor two-range/performance problem
×
2
C
×
P06B8:00
Illuminate
NVRAM malfunction
1
C, O
×
P0705:00
Illuminate
Illuminate
Transaxle range sensor circuit malfunction
×
1
C, O
×
P0706:00
Illuminate
Illuminate
Transaxle range sensor range/performance problem
×
2
C
×
P0711:00
Illuminate
Illuminate
TFT sensor range/performance problem
×
2
C
×
P0712:00
Illuminate
Illuminate
TFT sensor circuit low input
×
1
C, O
×
P0713:00
Illuminate
Illuminate
TFT sensor circuit high input
×
2
C
×
P0716:00
Illuminate
Illuminate
Turbine/Input shaft speed sensor range/performance problem
×
1
C
×
P0717:00
Illuminate
Illuminate
Open circuit in turbine/input shaft speed sensor circuit
×
1
C
×
P0721:00
Illuminate
Illuminate
Output shaft speed sensor range/performance problem
×
1
C
×
P0722:00
Illuminate
Illuminate
Open circuit in output shaft speed sensor circuit
×
1
C
×
P0729:00
6GR incorrect ratio
×
2
C
×
P0731:00
1GR incorrect ratio
×
2
C
×
P0732:00
2GR incorrect ratio
×
2
C
×
P0733:00
3GR incorrect ratio
×
2
C
×
P0734:00
4GR incorrect ratio
×
2
C
×
P0735:00
5GR incorrect ratio
×
2
C
×
P0736:00
Illuminate
Gear reverse incorrect ratio
×
2
C
×
P0741:00
Illuminate
Illuminate
TCC control solenoid stuck off
×
2
C
×
P0743:00
Illuminate
Illuminate
TCC control solenoid circuit malfunction
×
1
C, O
×
P0746:00
Illuminate
Illuminate
Pressure control solenoid stuck off
×
2
C
×
P0748:00
Illuminate
Illuminate
Pressure control solenoid circuit malfunction
×
1
C, O
×
P0751:00
Illuminate
Illuminate
Shift solenoid No.1 stuck off
×
2
C
×
P0752:00
Illuminate
Illuminate
Shift solenoid No.1 stuck on
×
2
C
×
P0753:00
Illuminate
Illuminate
Shift solenoid No.1 circuit malfunction
×
1
C, O
×
P0756:00
Illuminate
Illuminate
Shift solenoid No.2 stuck off
×
2
C
×
P0757:00
Illuminate
Illuminate
Shift solenoid No.2 stuck on
×
2
C
×
P0758:00
Illuminate
Illuminate
Shift solenoid No.2 circuit malfunction
×
1
C, O
×
P0761:00
Illuminate
Illuminate
Shift solenoid No.3 stuck off
×
2
C
×
P0762:00
Illuminate
Illuminate
Shift solenoid No.3 stuck on
×
2
C
×
P0763:00
Illuminate
Illuminate
Shift solenoid No.3 circuit malfunction
×
1
C, O
×
P0766:00
Illuminate
Illuminate
Shift solenoid No.4 stuck off
×
2
C
×
P0767:00
Illuminate
Illuminate
Shift solenoid No.4 stuck on
×
2
C
×
P0768:00
Illuminate
Illuminate
Shift solenoid No.4 circuit malfunction
×
1
C, O
×
P0771:00
Illuminate
Illuminate
On/off solenoid stuck off
×
2
C
×
P0772:00
Illuminate
Illuminate
On/off solenoid stuck on
×
2
C
×
P0773:00
Illuminate
Illuminate
On/off solenoid circuit malfunction
×
1
C, O
×
P0780:00
Illuminate
Illuminate
Gear shifting malfunction
×
2
C
×
P079A:00
Illuminate
Illuminate
Shift solenoid No.3 stuck off/On/off solenoid stuck on
×
2
C
×
P0819:00
M position switch/Up switch/Down switch signal error
×
1
C
×
P0842:00
Illuminate
Illuminate
Oil pressure switch No.1 stuck on
×
2
C
×
P0843:00
Illuminate
Illuminate
Oil pressure switch No.1 stuck off
×
2
C
×
P0847:00
Illuminate
Illuminate
Oil pressure switch No.2 stuck on
×
2
C
×
P0848:00
Illuminate
Illuminate
Oil pressure switch No.2 stuck off
×
2
C
×
P0872:00
Illuminate
Illuminate
Oil pressure switch No.3 stuck on
×
2
C
×
P0873:00
Illuminate
Illuminate
Oil pressure switch No.3 stuck off
×
2
C
×
P0877:00
Illuminate
Illuminate
Oil pressure switch No.4 stuck on
×
2
C
×
P0878:00
Illuminate
Illuminate
Oil pressure switch No.4 stuck off
×
2
C
×
P0882:00
Illuminate
TCM power supply voltage low
×
1
C
×
P0883:00
Illuminate
TCM power supply voltage high
×
1
C, O
×
P0C2C:00
Electric AT oil pump rotation malfunction
×
1
C
×
P1728:00
Clutch slippage
×
2
C
×
P1738:00
Illuminate
Automatic transaxle internal malfunction
×
2
C
×
P1784:00
Illuminate
Hi cut valve stuck off/R-3-5 cut valve stuck on
×
2
C
×
P181F:00
Electric AT oil pump/Electric AT oil pump relay circuit malfunction
×
1
C
×
P2712:00
Oil pump shift valve stuck
×
1
C
×
U0073:00
CAN system communication error (HS CAN)
×
1
C, O
×
U0074:00
CAN system communication error (local CAN between TCM and PCM)
×
1
C, O
×
U0100:00
Illuminate
Communication error to PCM (HS CAN)
×
1
C, O
×
U0115:00
Illuminate
Communication error to PCM (local CAN between TCM and PCM)
×
1
C, O
×
U0121:00
Illuminate
Communication error to DSC HU/CM
×
1
C, O
×
U0141:00
Communication error to BCM
×
1
C, O
×
U0155:00
Illuminate
Communication error to instrument cluster
×
1
C, O
×
U0442:00
Invalid data received from PCM (local CAN between TCM and PCM)
×
1
C, O
×

*1  ::C: CMDTC self test, O: KOEO self test