DTC TABLE [WATER HEATER SYSTEM]
id070228801700
DTC |
Malfunction location |
Detected condition |
Memory function |
Page |
---|---|---|---|---|
B1D24:11
|
Glow plug
|
Circuit short to ground
|
X
|
|
B1D24:15
|
Circuit short to power supply or open
|
X
|
||
B1D25:11
|
Fuel pump (water heater system)
|
Circuit short to ground
|
X
|
|
B1D25:15
|
Circuit short to power supply or open
|
X
|
||
B1D26:11
|
Blower fan
|
Circuit short to ground
|
X
|
|
B1D26:15
|
Circuit short to power supply or open
|
X
|
||
B1D29:93
|
No start, even after restart attempt
|
No operation
|
X
|
|
B1D30:93
|
No start in test mode
|
No operation
|
X
|
|
B1D31:94
|
Flame detected prior to normal operation
|
Unexpected operation
|
X
|
|
B1D32:92
|
Multiple flame interruption during heating cycle
|
Performance or incorrect operation
|
X
|
|
B1D34:68
|
Heater in lock out mode
|
Event information
|
X
|
|
U0001:88
|
HS-CAN communication bus
|
Bus off
|
X
|
|
U0100:00
|
Lost communication with PCM
|
No sub type information
|
X
|
|
U0140:00
|
Lost communication with BCM
|
No sub type information
|
X
|
|
U0155:00
|
Lost communication with instrument cluster
|
No sub type information
|
X
|
|
U3000:49
|
Control module
|
Internal electronic failure
|
X
|
|
U3003:16
|
Power supply circuit (battery voltage)
|
Circuit voltage below threshold
|
X
|
|
U3003:17
|
Circuit voltage above threshold
|
X
|