LIFTGATE LOCK ACTUATOR INSPECTION


id091400433200

1.  Disconnect the negative battery cable.

2.  Remove the liftgate upper trim. (See LIFTGATE UPPER TRIM REMOVAL/INSTALLATION.)

3.  Remove the liftgate side trim. (See LIFTGATE SIDE TRIM REMOVAL/INSTALLATION.)

4.  Remove the liftgate lower trim. (See LIFTGATE LOWER TRIM REMOVAL/INSTALLATION.)

5.  Remove the liftgate latch and lock actuator. (See LIFTGATE LATCH AND LOCK ACTUATOR REMOVAL/INSTALLATION.)

6.  Press the latch in using a flathead screwdriver to inspect the latch lever condition.

am6zzw00006930

7.  Apply battery positive voltage and connect the ground to each terminal, and then verify the operation.

am6zzw00003392

•  If not as indicated in the table, replace the liftgate latch and lock actuator.

Lock actuator operation

Terminal

B+

Ground

UNLATCH
D
B