DTC B1318
id060200801900
DTC
|
B1318
|
Battery power supply
|
|
DETECTION CONDITION
|
• Voltage of 10 V or less or 16 V or more detected by EPS control module internal ignition voltage observation.
|
||
POSSIBLE CAUSE
|
• Battery malfunction
• Generator malfunction
• Poor connection of EPS control module connector
• EPS control module connector or terminal malfunction
• Short to ground in wiring harness between EPS control module terminal 2P and battery
• EPS control module malfunction
|
||
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT POWER SUPPLY VOLTAGE USING M-MDS
• Turn the ignition switch off.
• Connect the M-MDS to the DLC-2.
• Turn the ignition switch to the ON position (engine off).
• Access B+ PID.
• Is the voltage normal?
|
Yes
|
Malfunction may be temporary. Go to Step 6.
|
No
|
Go to the next step.
|
||
2
|
INSPECT BATTERY
• Inspect the battery.
(See BATTERY INSPECTION [13B-MSP].)
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the battery, then go to Step 6.
|
||
3
|
INSPECT GENERATOR
• Inspect the generator.
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the generator, then go to Step 6.
|
||
4
|
INSPECT WHETHER MALFUNCTION IS CAUSED BY POOR CONNECTION OF EPS CONTROL MODULE OR PIN DEFORMATION
• Turn the ignition switch off.
• Inspect connection of the EPS control module and wiring harness.
• Disconnect the EPS control module connector.
• Inspect whether malfunction is caused by bent or poorly connected EPS control module connector pin.
• Are the connector connection, connector pins, and wiring harness normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the malfunction connector wiring harness, then go to Step 6.
|
||
5
|
INSPECT EPS CONTROL MODULE POWER SUPPLY CIRCUIT FOR SHORT TO GROUND
• Disconnect the battery positive terminal.
• Inspect for continuity between EPS control module terminal 2P and ground.
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for short to ground between EPS control module terminal 2P and ground, then go to Step 6.
|
No
|
Go to the next step.
|
||
6
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Clear the DTC from the memory.
• Turn the ignition switch off.
• Start the engine.
• Is the same DTC present?
|
Yes
|
Replace the EPS control module, then go to the next step.
|
No
|
Go to the next step.
|
||
7
|
VERIFY AFTER REPAIR PROCEDURE
• Are any other DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|