Defrosting Insufficient
1.
Inspect for an obstruction in both of the defroster nozzles.
Perform the following steps, as necessary:
^
Remove any foreign objects.
^
Repair any loose instrument panel pad that blocks an outlet.
2.
Inspect for the proper operation of the defroster
air door.
3.
Replace the
defroster actuator if faulty.
4.
Inspect for insufficient heating. Refer to Heating Performance Diagnostic.