Yaw Rate Sensor: Testing and Inspection
G Sensor Inspection Reference: G Sensor Removal and Installation Connect positive cable of
12 volt battery to (1)terminal of sensor and ground cable to (3) terminal. Then using voltmeter, check voltage between (2) terminal and (3) terminal.
If measured voltage is not as specified, replace sensor with bracket.
G sensor specifications: