Pulse Generator A
INSPECTION CONDITION CRITERION VALUE
D range, stopping state 0 - 400 RPM
D range, 3rd speed, 50 MPH 1800 - 2200 RPM
D range, 4th speed, 50 MPH 1200 - 1600 RPM
POSSIBLE CAUSE (OR REMEDY) FOR THE ABNORMALITY
- Defective pulse generator A or harness
- Defective shield of pulse generator A
- External noise invasion
- Slip of kick-down brake