No.5 DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING [POWER WINDOW SYSTEMS (EXTERIOR OPEN/CLOSE FUNCTION)]


id090361809000

5

DOOR GLASS STOPS BEFORE FULLY OPENING/CLOSING

POSSIBLE CAUSE
•  Power window main switch malfunction
•  Power window subswitch (passenger side) malfunction
•  Power window motor malfunction
•  Battery malfunction (low voltage)
•  Door glass improper installation
•  Power window initialization procedure error
•  Keyless control module malfunction
•  BCM malfunction
•  Keyless entry system signal reception error (outside operation area, radio signal interference)

Diagnostic Procedure

Step

Inspection

Action

1
•  Operate the door glass in auto/manual by operating the power window main switch/power window subswitch (passenger side).
•  Does the door glass stop before fully opening/closing using either operation?
Yes
Inspect the following parts, and repair or replace.
•  Power window main switch
•  Power window subswitch (passenger side)
•  Power window motor )
•  Battery (low voltage)
•  Door glass (Installation condition)
No
Go to the next step.
2
•  Inspect the operation of the door glass by repeating Step 1 above.
•  Does the door glass stop before fully opening/closing while in auto operation?
Yes
Perform the power window initialization procedure.
No
Go to the next step.
3
•  Open the door glass by operating the transmitter.
•  Does the door glass stop moving before it reaches the fully-opened position with the button on the transmitter held pressed?
Yes
Inspect the following parts, and repair or replace.
•  Keyless control module (Vehicles with advanced keyless system)
No
Go to the next step.
4
•  Close the door glass by operating the transmitter.
•  Does the door glass stop moving before it reaches the fully-closed position with the button on the transmitter held pressed?
Yes
Inspect the following parts, and repair or replace.
•  Keyless control module (Vehicle with advanced keyless system)
•  Keyless entry system signal reception error (outside operation area, radio signal interference)
No
Reinspect for malfunction recurrence.If the malfunction is not corrected, repeat the procedure from Step 1.