NO.1 ANY OF THE FOLLOWING LIGHTS DO NOT ILLUMINATE WITH SWITCH THE IGNITION TO ON: (ABS WARNING LIGHT, BRAKE SYSTEM WARNING LIGHT, DSC INDICATOR LIGHT AND/OR DSC OFF LIGHT) [DYNAMIC STABILITY CONTROL (DSC)]


id0403b2891900

1

Any of the following lights do not illuminate with switch the ignition to ON:

•  ABS warning light
•  Brake system warning light
•  DSC indicator light
•  DSC OFF light
Possible cause
•  Instrument cluster power supply malfunction
―  Short to ground in ignition power supply circuit
―  Instrument cluster power supply fuse malfunction
•  Open circuit in instrument cluster power supply circuit
•  Open circuit in instrument cluster ground circuit
•  DSC HU/CM DTC is stored
•  DSC HU/CM power supply malfunction
―  Short to ground in ignition power supply circuit
―  DSC HU/CM power supply fuse malfunction
•  Open circuit in DSC HU/CM power supply circuit
•  Open circuit in DSC HU/CM ground circuit
•  DSC HU/CM malfunction
•  Instrument cluster DTC is stored
•  Instrument cluster malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
VERIFY WHETHER MALFUNCTION IS IN WARNING LIGHT AND INDICATOR LIGHT’S COMMON POWER SUPPLY OR IN OTHER WARNING LIGHTS AND INDICATOR LIGHT
•  Connect the M-MDS to the DLC-2.
•  Turn on all warning lights and indicator lights using the instrument cluster PID WL+IL of active command modes.
•  Do the other warning and indicator lights illuminate?
Yes
Go to Step 5.
No
If the communication error message is displayed on M-MDS screen:
•  Go to the next step.
If the communication error message is not displayed:
•  Replace the instrument cluster.
2
INSPECT INSTRUMENT CLUSTER POWER SUPPLY FUSE
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Inspect the instrument cluster ignition power supply fuse.
•  Is the fuse normal?
Yes
Go to the next step.
No
Inspect for short to ground in ignition power supply circuit.
Repair or replace if necessary.
Install the appropriate amperage fuse.
*3
INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT
•  Reconnect the negative battery cable.
•  Switch the ignition to ON.
•  Measure the voltage between instrument cluster terminal 2S (wiring harness-side) and body ground.
•  Is the voltage approx. 12 V?
Yes
Go to the next step.
No
Repair or replace the wiring harness for a possible open circuit.
*4
INSPECT INSTRUMENT CLUSTER GROUND CIRCUIT FOR OPEN CIRCUIT
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Disconnect the instrument cluster connector.
•  Inspect for continuity between instrument cluster terminal 2K (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Replace the instrument cluster (open circuit in instrument cluster).
No
Repair or replace the wiring harness for a possible open circuit.
5
CONFIRM DSC HU/CM DTC
•  Retrieve the DSC HU/CM DTC using the M-MDS.
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
If the communication error message is displayed in M-MDS screen:
•  Go to the next step.
If the communication error message is not displayed:
•  Go to Step 9.
6
INSPECT DSC HU/CM POWER SUPPLY FUSE
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Inspect the DSC HU/CM ignition power supply fuse.
•  Is the fuse normal?
Yes
Go to the next step.
No
Inspect for short to ground in ignition power supply circuit.
Repair or replace if necessary.
Install the appropriate amperage fuse.
*7
INSPECT DSC HU/CM POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT
•  Reconnect the negative battery cable.
•  Switch the ignition to ON.
•  Measure the voltage between DSC HU/CM terminal Y (wiring harness-side) and body ground.
•  Is the voltage approx. 12 V?
Yes
Go to the next step.
No
Repair or replace the wiring harness for a possible open circuit.
*8
INSPECT DSC HU/CM GROUND CIRCUIT FOR OPEN CIRCUIT
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Disconnect the DSC HU/CM connector.
•  Inspect for continuity between DSC HU/CM terminal B (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Replace the DSC HU/CM (open circuit in DSC HU/CM).
No
Repair or replace the wiring harness for a possible open circuit.
9
CONFIRM INSTRUMENT CLUSTER DTC
•  Retrieve the instrument cluster DTC using the M-MDS.
•  Are any DTCs present?
Yes
Go to the applicable DTC troubleshooting.
No
Replace the instrument cluster.

•  When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while doing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harness are connected correctly and undamaged.