DTC B108C:23 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
id09021c399600
DESCRIPTION |
Short to ground in push button start 2 circuit |
---|---|
DETECTION CONDITION
|
• Keyless control module detects the push button start 2 signal for 120 s or more.
|
POSSIBLE CAUSE
|
• Push button start connector or terminals malfunction
• Keyless control module connector or terminals malfunction
• Short to ground in wiring harness between the following terminals:
• Push button start malfunction
• Keyless control module malfunction
|
![]() |
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT PUSH BUTTON START CONNECTOR AND TERMINALS
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Disconnect the push button start connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 5.
|
No
|
Go to the next step.
|
||
2
|
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
• Disconnect the keyless control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT PUSH BUTTON START CIRCUIT FOR SHORT TO GROUND
• Push button start and keyless control module connectors are disconnected.
• Inspect for continuity between the following terminal (wiring harness-side) and body ground:
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for a possible short to ground, then go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
INSPECT PUSH BUTTON START
• Inspect the push button start.
• Is there any malfunction?
|
Yes
|
Replace the push button start, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect the disconnected connectors.
• Reconnect the negative battery cable.
• Operate the advanced key to activate the keyless control module.
• Clear the DTC from the keyless control module using the M-MDS.
• Operate the advanced key to activate the keyless control module.
• Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|