SECURITY LIGHT: 16, DTC: U0100:87/P1260:00 [IMMOBILIZER SYSTEM (KEYLESS ENTRY SYSTEM)]


id0902e5356800

DTC

Security light flashing pattern

16

Communication error to PCM (No response)

M-MDS display

Instrument cluster

U0100:87

PCM

P1260:00

DETECTION CONDITION
•  Communication error between instrument cluster and PCM (No response).
POSSIBLE CAUSE
•  Wiring harness between instrument cluster and PCM malfunction (CAN line)
•  Instrument cluster malfunction
•  PCM malfunction


Diagnostic Procedure

STEP

INSPECTION

ACTION

1
VERIFY DTCs
•  Clear the DTC from the instrument cluster using the M-MDS.
•  Verify the immobilizer system DTC using the M-MDS.
•  Is the following DTC present?
―  U0001:88
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
VERIFY INSTRUMENT CLUSTER MALFUNCTION
•  Clear the DTC from the instrument cluster using the M-MDS.
•  Verify the immobilizer system DTC using the M-MDS.
•  Is the following DTC present?
―  Instrument cluster: U0100:87
―  PCM: P1260:00
Yes
Replace the instrument cluster and program the immobilizer system-related parts.
Go to the next step.
No
Go to Step 4.
3
VERIFY TROUBLESHOOTING COMPLETED
•  Clear the DTC from the instrument cluster using the M-MDS.
•  Verify the immobilizer system DTC using the M-MDS.
•  Is the following DTC present?
―  Instrument cluster: U0100:87
―  PCM: P1260:00
Yes
Replace the PCM, then go to the next step.
No
Go to the next step.
4
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.