DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]


id0702k2801700

X: Applicable
-: Not applicable

DTC

Warning lamp

Malfunction location

Detected condition

Fail safe

Drive cycle

Self test type*1

Memory function

Page

B1081:71
•  Driver-side air mix actuator (L.H.D.)
•  Passenger-side air mix actuator (R.H.D.)
Motor lock
X
C
X
B1082:71
•  Passenger-side air mix actuator (L.H.D.)
•  Driver-side air mix actuator (R.H.D.)
Motor lock
X
C
X
B1086:71
Airflow mode actuator
Motor lock
X
C
X
B1A61:11
Cabin temperature sensor
Circuit short to ground
X
C, D
X
B1A61:13
Circuit open
X
C, D
X
B1A63:12
Solar radiation sensor (RH)
Circuit shot to power supply
C, D
X
B1A63:13
Circuit open
D
X
B1A64:12
Solar radiation sensor (LH)
Circuit shot to power supply
C, D
X
B1A64:13
Circuit open
D
X
B1B71:11
Evaporator temperature sensor
Circuit short to ground
X
C, D
X
B1B71:13
Circuit open
X
C, D
X
B1C1A:12
•  Driver-side air mix actuator (potentiometer) (L.H.D.)
•  Passenger-side air mix actuator (potentiometer) (R.H.D.)
Circuit short to power supply
X
C, D
X
B1C1A:13
Circuit open
X
C, D
X
B1C1B:12
•  Passenger-side air mix actuator (potentiometer) (L.H.D.)
•  Driver-side air mix actuator (potentiometer) (R.H.D.)
Circuit short to power supply
X
C, D
X
B1C1B:13
Circuit open
X
C, D
X
B1C1C:12
Airflow mode actuator (potentiometer)
Circuit short to power supply
X
C, D
X
B1C1C:13
Circuit open
X
C, D
X
U0010:88
CAN communication system
Bus off
X
C
X
U0155:00
Lost communication with instrument cluster
No sub type information
X
C, D
X
U0423:68
Invalid date received from Instrument cluster
Event information
X
C, D
X
U200D:11
Climate control unit circuit voltage (+5V)
Circuit short to ground
C, D
X
U2300:54
Configuration error
Data not received
C, D
X
U2300:55
Not configured
C, D
U2300:56
Ineffective/non-interchangeable data read
C, D
X
U2300:64
Error value read
C, D
X
U3000:49
Climate control unit
Climate control unit internal malfunction
C, D
X
U3003:16
Climate control unit power supply voltage (B+, IG1)
Power supply voltage decreases (10 V or less)
X
C, D
X
U3003:17
Climate control unit power supply voltage (B+, IG1)
Power supply voltage increases (17.3 V or more (B+, IG1))
X
C, D
X
U300E:13
Climate control unit power supply circuit open (IG1)
Circuit open
C, D
X

*1  :C: CMDTC self test, D: ODDTC self test