DTC U3003:16 [INSTRUMENT CLUSTER]


id0902e8999400

DTC U3003:16

Battery positive voltage is low

Detection Condition
•  Instrument cluster power supply voltage less than 10 V.
Possible Causes
•  Battery malfunction
•  Generator malfunction
•  BCM connector or terminals malfunction
•  Open circuit or short to ground in instrument cluster power supply circuit
―  Short to ground in wiring harness between BCM terminal 1O and battery positive terminal
―  ROOM 15 A fuse malfunction
―  MAIN 200 A fuse malfunction
―  Open circuit in wiring harness between BCM terminal 1O and battery positive terminal
•  BCM malfunction
•  Instrument cluster connector or terminals malfunction
•  Open circuit or short to ground in instrument cluster power supply circuit
―  Short to ground in wiring harness between the following:
•  BCM terminal 3P―Instrument cluster terminal 2U
•  Battery positive terminal―Instrument cluster terminal 2S
―  METER 10 A fuse malfunction
―  IG KEY 1 40 A fuse malfunction
―  MAIN 200 A fuse malfunction
―  Open circuit in wiring harness between the following:
•  BCM terminal 3P―Instrument cluster terminal 2U
•  Battery positive terminal―Instrument cluster terminal 2S
•  Instrument cluster malfunction


System Wiring Diagram

am2zzw00005903

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM PCM DTC INSPECTION
•  Perform the PCM DTC inspection using the M-MDS.
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
INSPECT BATTERY
•  Is there any malfunction?
Yes
Recharge or replace the battery, then go to Step 9.
No
Go to the next step.
3
INSPECT GENERATOR
•  Is there any malfunction?
Yes
Replace the generator, then go to Step 9.
No
Go to the next step.
4
INSPECT BCM CONNECTOR AND TERMINALS
•  Turn the ignition switch to the LOCK position.
•  Disconnect the negative battery cable.
•  Disconnect the BCM connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 9.
No
Go to the next step.
5
INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT AND SHORT TO GROUND
•  Verify that the BCM connector is disconnected.
•  Reconnect the negative battery cable.
•  Measure the voltage at the BCM terminal 1O (wiring harness-side).
•  Is the voltage B+?
Yes
Go to the next step.
No
Inspect the ROOM 15 A fuse and MAIN 200 A fuse.
•  If the fuse is melt:
―  Repair or replace the wiring harness for a possible short to ground.
―  Replace the fuse.
•  If the fuse is deterioration:
―  Replace the fuse.
•  If the fuse is normal:
―  Repair or replace the wiring harness for a possible open circuit.
Go to Step 9.
6
INSPECT BCM
•  Disconnect the negative battery cable.
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Measure the voltage at the following terminals (wiring harness-side):
―  BCM terminal 1O
―  BCM terminal 3P
•  Is the voltage normal?
Yes
Go to the next step.
No
Replace the BCM, then go to Step 9.
7
INSPECT INSTRUMENT CLUSTER CONNECTOR AND TERMINALS
•  Disconnect the negative battery cable.
•  Disconnect the instrument cluster connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 9.
No
Go to the next step.
8
INSPECT INSTRUMENT CLUSTER POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT AND SHORT TO GROUND
•  Verify that the instrument cluster connector is disconnected.
•  Reconnect the negative battery cable.
•  Turn the ignition switch to the ON position.
•  Measure the voltage at the following terminals (wiring harness-side):
―  Instrument cluster terminal 2U
―  Instrument cluster terminal 2S
•  Is the voltage B+?
Yes
Go to the next step.
No
Inspect the METER 10 A fuse and IG KEY 1 40 A fuse and MAIN 200 A fuse.
•  If the fuse is melt:
―  Repair or replace the wiring harness for a possible short to ground.
―  Replace the fuse.
•  If the fuse is deterioration:
―  Replace the fuse.
•  If the fuse is normal:
―  Repair or replace the wiring harness for a possible open circuit.
Go to the next step.
9
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Clear the DTC using the M-MDS.
•  Perform the instrument cluster DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the instrument cluster.
Go to the next step.
No
Go to the next step.
10
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.