DTC B10E7:12 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]


id09021c399700

DESCRIPTION

Short to power supply in IG1 relay circuit

DETECTION CONDITION
•  IG1 relay output monitor is on for 0.5 s when the ignition switch is off.
POSSIBLE CAUSE
•  Relay block connector or terminals malfunction
•  Keyless control module connector or terminals malfunction
•  Short to power supply in wiring harness between the following terminals:
―  Relay block terminal 2G—Keyless control module terminal 3D
•  Relay block malfunction
•  Keyless control module malfunction

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT RELAY BLOCK CONNECTOR AND TERMINALS
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Disconnect the relay block connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 5.
No
Go to the next step.
2
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
•  Disconnect the keyless control module connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 5.
No
Go to the next step.
3
INSPECT IG1 RELAY OUTPUT CIRCUIT FOR SHORT TO POWER SUPPLY
•  Relay block and keyless control module connectors are disconnected.
•  Measure the voltage at the following terminal (wiring harness-side):
―  Relay block terminal 2G
•  Is there any voltage?
Yes
Repair or replace the wiring harness for a possible short to power supply, then go to Step 5.
No
Go to the next step.
4
INSPECT RELAY BLOCK
•  Is there any malfunction?
Yes
Replace the relay block, then go to the next step.
No
Go to the next step.
5
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect the disconnected connectors.
•  Switch the ignition to off using the advanced key.
•  Clear the DTC from the keyless control module using the M-MDS.
•  Switch the ignition to off using the advanced key.
•  Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Replace the keyless control module, then go to the next step.
No
Go to the next step.
6
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.