DTC B10E7:12 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
id09021c399700
DESCRIPTION |
Short to power supply in IG1 relay circuit |
---|---|
DETECTION CONDITION
|
• IG1 relay output monitor is on for 0.5 s when the ignition switch is off.
|
POSSIBLE CAUSE
|
• Relay block connector or terminals malfunction
• Keyless control module connector or terminals malfunction
• Short to power supply in wiring harness between the following terminals:
• Relay block malfunction
• Keyless control module malfunction
|
![]() |
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT RELAY BLOCK CONNECTOR AND TERMINALS
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Disconnect the relay block connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 5.
|
No
|
Go to the next step.
|
||
2
|
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
• Disconnect the keyless control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 5.
|
No
|
Go to the next step.
|
||
3
|
INSPECT IG1 RELAY OUTPUT CIRCUIT FOR SHORT TO POWER SUPPLY
• Relay block and keyless control module connectors are disconnected.
• Reconnect the negative battery cable.
• Measure the voltage at the following terminal (wiring harness-side):
• Is there any voltage?
|
Yes
|
Repair or replace the wiring harness for a possible short to power supply, then go to Step 5.
|
No
|
Go to the next step.
|
||
4
|
INSPECT RELAY BLOCK
• Inspect the relay block.
• Is there any malfunction?
|
Yes
|
Replace the relay block, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect the disconnected connectors.
• Reconnect the negative battery cable.
• Switch the ignition to off using the advanced key.
• Clear the DTC from the keyless control module using the M-MDS.
• Switch the ignition to off using the advanced key.
• Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|