DTC P1794:17 [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
id09021c933200
DESCRIPTION |
High voltage in power supply circuit (+B2) |
---|---|
DETECTION CONDITION
|
• Keyless control module power supply circuit (+B2) voltage is 16.5 V or more for 0.5 s.
|
POSSIBLE CAUSE
|
• PCM DTC is stored
• Generator malfunction
• Keyless control module malfunction
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
CONFIRM PCM DTC
• Perform the PCM DTC inspection using the M-MDS.
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See DTC TABLE [MZR 1.5, MZR 1.6].)
(See DTC TABLE [MZR 2.0, MZR 2.5].)
(See DTC TABLE [MZR-CD 2.2].)
(See DTC TABLE [SKYACTIV-G 2.0].)
|
No
|
Go to the next step.
|
||
2
|
INSPECT GENERATOR
• Inspect the generator.
• Is there any malfunction?
|
Yes
|
Replace the generator, then go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY TROUBLESHOOTING COMPLETED
• Operate the advanced key to activate the keyless control module.
• Clear the DTC from the keyless control module using the M-MDS.
• Operate the advanced key to activate the keyless control module.
• Perform the advanced keyless entry and push button start system DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Replace the keyless control module, then go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|