Diagnostic Procedure
• When performing the asterisked (*) troubleshooting inspection, slightly shake the wiring harness and connectors while performing the inspection to determine whether poor contact points are the cause of any intermittent malfunction. If there is a problem, verify that the connectors, terminals and the wiring harness are connected correctly and undamaged.
STEP
|
INSPECTION
|
ACTION
|
|
---|---|---|---|
1
|
VERIFY THAT POWER RETRACTABLE HARDTOP INDICATOR LIGHT ILLUMINATES
• Turn the ignition switch to the ON position.
• Verify the power retractable hardtop indicator light status.
• Does the power retractable hardtop indicator light flash?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 3.
|
||
2
|
VERIFY THAT PRESENT MALFUNCTION DTC STORED
• Connect the M-MDS to DLC-2.
• Retrieve DTC for power retractable hardtop control module.
• Is there a DTC present?
|
Yes
|
Go to the appropriate DTC inspection.
|
No
|
Go to symptom troubleshooting "No.2 POWER RETRACTABLE HARDTOP INDICATOR LIGHT IS FLASHING" procedure.
|
||
3
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN DECK PANEL OR ELSEWHERE
• Verify the malfunction symptom.
• Does the deck panel operation stop during the open or close operation?
|
Yes
|
Stops during the deck panel open operation:
Go to the next step.
Stops during the deck panel close operation:
Go to Step 7.
|
No
|
Go to Step 14.
|
||
4
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN DECK PANEL OPEN POSITION SWITCH OR ELSEWHERE
• Monitor the power retractable hardtop control module PID DECK_OP using the M-MDS at the position where the deck panel does not operate.
• Is the monitor value on (deck panel fully open)?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 10.
|
||
5
|
INSPECT DECK PANEL OPEN POSITION SWITCH
• Inspect the deck panel open position switch.
• Is the deck panel open position switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the deck panel link.
|
||
6*
|
INSPECT DECK PANEL OPEN POSITION SWITCH WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (16-pin) and the deck panel open position switch connectors.
• Verify the continuity between power retractable hardtop control module terminal 3F and ground.
• Is there continuity?
|
Yes
|
Adjust the deck panel open position switch installation.
|
No
|
Repair for a short to the ground circuit.
|
||
7
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN DECK PANEL CLOSE POSITION SWITCH OR ELSEWHERE
• Monitor the power retractable hardtop control module PID DECK_CL using the M-MDS when the position where the deck panel could not operate.
• Is the monitor value ON (deck panel fully closed)?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 10.
|
||
8
|
INSPECT DECK PANEL CLOSE POSITION SWITCH
• Inspect the deck panel close position switch.
• Is the deck panel close position switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the deck panel link.
|
||
9*
|
INSPECT DECK PANEL CLOSE POSITION SWITCH WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (16-pin) and the deck panel close position switch connectors.
• Verify that the continuity between the power retractable hardtop control module terminal 3F and ground.
• Is there any continuity?
|
Yes
|
Adjust the deck panel close position switch installation.
|
No
|
Repair for a short to the ground circuit.
|
||
10*
|
INSPECT DECK PANEL MOTOR WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (16-pin, 24-pin), and deck panel motor (6-pin) connectors on both sides.
• Inspect for an open or short circuit and poor connection at the following terminals:
• Is there an open or short circuit, or a poor connection?
|
Yes
|
Repair or replace malfunctioning part.
|
No
|
Go to the next step.
|
||
11
|
INSPECT DECK PANEL MOTOR
• Inspect the deck panel motors on both sides.
(See DECK PANEL MOTOR INSPECTION.)
• Are both deck panel motors normal?
|
Yes
|
Go to the next step.
|
No
|
Replace suspected deck panel motor.
|
||
12
|
INSPECT DECK PANEL MOTOR HALL SENSOR
• Measure the pulse profiles for the following power retractable hardtop control module (24-pin) while the deck panel is operating using the oscilloscope.
• Is the pulse profile normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the suspected deck panel motor.
|
||
13
|
INSPECT POWER RETRACTABLE HARDTOP LINK MECHANICS
• Inspect the deck panel link mechanics.
• Is there any restriction or hesitation for the deck panel operation?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Go to Step 25.
|
||
14
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN ROOF OR ELSEWHERE
• Verify that malfunction symptom.
• Does the roof operation stop during the open or close operation?
|
Yes
|
Stops during the roof open operation:
Go to the next step.
Stops during the roof close operation:
Go to Step 18.
|
No
|
Go to Step 25.
|
||
15
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER RETRACTABLE HARDTOP OPEN POSITION SWITCH OR ELSEWHERE
• Monitor the power retractable hardtop control module PID RHT_OP using the M-MDS at the position where the roof does operate.
• Is the monitor value on (roof fully open)?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 22.
|
||
16
|
INSPECT POWER RETRACTABLE HARDTOP OPEN POSITION SWITCH
• Inspect the power retractable hardtop open position switch.
• Is the power retractable hardtop open position switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the power retractable hardtop limit switch.
|
||
17*
|
INSPECT POWER RETRACTABLE HARDTOP OPEN POSITION SWITCH WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (24-pin) and the power retractable hardtop open position switch connectors.
• Verify that continuity between power retractable hardtop control module terminal 1T-ground.
• Is there continuity?
|
Yes
|
Adjust the power retractable hardtop open position switch installation.
|
No
|
Repair for a short to the ground circuit.
|
||
18
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN POWER RETRACTABLE HARDTOP CLOSE POSITION SWITCH OR ELSEWHERE
• Monitor the power retractable hardtop control module PID RHT_CL using the M-MDS at the position where the roof could not operate.
• Is the monitor value on (roof fully closed)?
|
Yes
|
Go to the next step.
|
No
|
Go to Step 20.
|
||
19
|
INSPECT POWER RETRACTABLE HARDTOP CLOSE POSITION SWITCH
• Inspect the power retractable hardtop close position switch.
• Is the power retractable hardtop close position switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the power retractable hardtop limit switch.
|
||
20*
|
INSPECT POWER RETRACTABLE HARDTOP CLOSE POSITION SWITCH WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (24-pin) and the deck panel close position switch connectors.
• Verify that continuity between power retractable hardtop control module terminal 1F-ground.
• Is there any continuity?
|
Yes
|
Adjust the power retractable hardtop close position switch installation position.
|
No
|
Repair for a short to the ground circuit.
|
||
21*
|
INSPECT ROOF MOTOR WIRING HARNESS
• Turn the ignition switch to the LOCK position.
• Disconnect the power retractable hardtop control module (16-pin, 24-pin), and the roof motor (6-pin) connector on both sides.
• Inspect for the open or short circuit and poor connection at the following terminals:
• Is there an open or short circuit, or a poor connection?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Go to the next step.
|
||
22
|
INSPECT ROOF MOTOR
• Inspect the both side roof motor hall sensors on both side.
(See ROOF MOTOR INSPECTION.)
• Are both roof motors normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the suspected roof motor.
|
||
23
|
INSPECT ROOF MOTOR HALL SENSOR
• Measure the pulse profiles for the following power retractable hardtop control module (24-pin) while the roof is operating using the oscilloscope.
• Is the pulse profile normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the suspected roof motor.
|
||
24
|
INSPECT POWER RETRACTABLE HARDTOP LINK MECHANICS
• Inspect the roof link mechanics.
• Does the roof operation stop during open or close operation?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Go to the next step.
|
||
25
|
INSPECT POWER RETRACTABLE HARDTOP SWITCH
• Remove the power retractable hardtop switch.
• Measure the resistance between power retractable hardtop switch connector (component side) terminals A and F.
• Is the resistance normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the power retractable hardtop switch.
|
||
26*
|
INSPECT POWER RETRACTABLE HARDTOP SWITCH WIRING HARNESS
• Turn the ignition switch to the ON position.
• Disconnect the power retractable hardtop control module (24-pin) and power retractable hardtop switch connectors.
• Inspect for an open or short circuit and poor connection between the power retractable hardtop control module terminal 1H and the power retractable hardtop switch terminal F.
• Is there any open or short circuit, or poor connection?
|
Yes
|
Repair or replace the malfunctioning part.
|
No
|
Replace the power retractable hardtop control module.
|