DTC U3003:17 [BCM]


id0902f5310200


Description

•  BCM power supply voltage malfunction

Detection Condition

•  BCM power supply voltage is high.

Possible Causes

•  Battery malfunction
•  Generator malfunction
•  BCM malfunction

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DTC INSPECTION
•  Clear the DTCs using the M-MDS.
•  Perform the BCM DTC inspection using the M-MDS.
•  Is the DTC U3003:17 present?
Yes
Go to the next step.
No
DTC troubleshooting completed.
2
INSPECT PCM DTC
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
3
INSPECT BATTERY
•  Is there any malfunction?
Yes
Replace the battery, then go to Step 5.
No
Go to the next step.
4
INSPECT GENERATOR
•  Is there any malfunction?
Yes
Replace the generator, then go to the next step.
No
Go to the next step.
5
VERIFY TROUBLESHOOTING COMPLETED
•  Clear the DTCs using the M-MDS.
•  Perform the BCM DTC inspection using the M-MDS.
•  Is the DTC U3003:17 present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the BCM.
Go to the next step.
No
Go to the next step.
6
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.