DTC U3003:16 [AFS (ADAPTIVE FRONT LIGHTING SYSTEM)]


id0902g9935200

DESCRIPTION

Low power supply circuit voltage

DETECTION CONDITION
•  AFS control module power supply circuit voltage is lower than 9 V for 10 s or more, while the ignition is ON.
POSSIBLE CAUSE
•  PCM DTC is stored.
•  Battery malfunction
•  Generator malfunction
•  AFS control module connector or terminals malfunction
•  AFS control module power supply circuit malfunction
―  Short to ground in wiring harness between METER 15 A fuse and AFS control module terminal H
―  METER 15 A fuse malfunction
―  Open circuit in wiring harness between ignition switch (IG1)*1/IG1 relay*2 and AFS control module terminal H
•  AFS control module malfunction

*1  :Vehicles without advanced keyless entry and push button start system
*2  :Vehicles with advanced keyless entry and push button start system

Diagnostic Procedure

STEP

INSPECTION

ACTION

1
CONFIRM PCM DTC
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
INSPECT BATTERY
•  Is there any malfunction?
Yes
Recharge or replace the battery, then go to Step 6.
No
Go to the next step.
3
INSPECT GENERATOR
•  Is there any malfunction?
Yes
Replace the generator, then go to Step 6.
No
Go to the next step.
4
INSPECT AFS CONTROL MODULE CONNECTOR AND TERMINALS
•  Switch the ignition to off.
•  Disconnect the AFS control module connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 6.
No
Go to the next step.
5
INSPECT AFS CONTROL MODULE POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT AND SHORT TO GROUND
•  Verify that the AFS control module connector is disconnected.
•  Switch the ignition to ON.
•  Measure the voltage at the AFS control module terminal H (wiring harness-side).
•  Is the voltage B+?
Yes
Go to the next step.
No
Inspect the METER 15 A fuse.
•  If the fuse is blown:
―  Repair or replace the wiring harness for a possible short to ground.
―  Replace the fuse.
•  If the fuse is deterioration:
―  Replace the fuse.
•  If the fuse is normal:
―  Repair or replace the wiring harness for a possible open circuit.
Go to the next step.
6
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Clear the DTC from the AFS control module using the M-MDS.
•  Switch the ignition to ON and wait for 10 s or more.
•  Perform the AFS control module DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the AFS control module.
Go to the next step.
No
Go to the next step.
7
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.