DTC C1137:12 [BCM]


id0902f5415400


Description

•  TR switch (ATX)/Back-up light switch (MTX) circuit malfunction

Detection Condition

ATX
•  Short to power supply in TR switch circuit with the selector lever not in R position.
MTX
•  Short to power supply in back-up light switch circuit with the shift lever not in R position (back-up light switch off).

Possible Causes

•  TR switch (ATX)/Back-up light switch (MTX) connector or terminals malfunction
•  TR switch (ATX)/Back-up light switch (MTX) malfunction
•  BCM connector or terminals malfunction
•  Short to power supply in wiring harness between the following terminals:
―  TR switch terminal D—BCM terminal 2H (ATX)
―  Back-up light switch terminal B—BCM terminal 2H (MTX)
―  Back-up light (LH)/(RH) terminal A—BCM terminal 7A
•  BCM malfunction

System Wiring Diagram

am6zzw00007172

Diagnostic Procedure

Step

Inspection

Action

1
PERFORM DTC INSPECTION
•  Clear the DTCs using the M-MDS.
•  Perform the BCM DTC inspection using the M-MDS under the following condition:
―  Selector lever not in R position (ATX)
―  Shift lever not in R position (back-up light switch off) (MTX)
•  Is the DTC C1137:12 present?
Yes
Go to the next step.
No
DTC troubleshooting completed.
2
INSPECT TR SWITCH (ATX)/BACK-UP LIGHT SWITCH (MTX) CONNECTOR CONDITION
•  Switch the ignition to off.
•  Disconnect the negative battery cable.
•  Disconnect the TR switch (ATX)/back-up light switch (MTX) connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 6.
No
Go to the next step.
3
INSPECT TR SWITCH (ATX)/BACK-UP LIGHT SWITCH (MTX)
•  Inspect the TR switch (ATX)/back-up light switch (MTX).
•  Is there any malfunction?
Yes
Replace the TR switch (ATX)/back-up light switch (MTX), then go to Step 6.
No
Go to the next step.
4
INSPECT BCM CONNECTOR CONDITION
•  Disconnect the BCM connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 6.
No
Go to the next step.
5
INSPECT TR SWITCH (ATX)/BACK-UP LIGHT SWITCH (MTX) CIRCUIT FOR SHORT TO POWER SUPPLY
•  TR switch (ATX)/back-up light switch (MTX) and BCM connectors are disconnected.
•  Reconnect the negative battery cable.
•  Switch the ignition to ON.
•  Measure the voltage at the following terminals (wiring harness-side):
―  TR switch terminal D (ATX)
―  Back-up light switch terminal B (MTX)
―  Back-up light (LH)/(RH) terminal A
•  Can the voltage be measured?
Yes
Repair or replace the wiring harness for a possible short to power supply, then go to the next step.
No
Go to the next step.
6
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Clear the DTCs using the M-MDS.
•  Perform the BCM DTC inspection using the M-MDS under the following condition:
―  Selector lever not in R position (ATX)
―  Shift lever not in R position (back-up light switch off) (MTX)
•  Is the DTC C1137:12 present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the BCM.
Go to the next step.
No
Go to the next step.
7
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.