DTC U3003:16 [AFS (ADAPTIVE FRONT LIGHTING SYSTEM)]
id0902g9935200
DESCRIPTION |
Low power supply circuit voltage |
---|---|
DETECTION CONDITION
|
• AFS control module power supply circuit voltage is lower than 9 V for 10 s or more, while the ignition is ON.
|
POSSIBLE CAUSE
|
• PCM DTC is stored
• Battery malfunction
• Generator malfunction
• AFS control module connector or terminals malfunction
• Open circuit or short to ground in AFS control module power supply circuit:
• AFS control module malfunction
|
![]() |
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
CONFIRM PCM DTC
• Perform the DTC Reading Procedure to confirm the PCM DTC.
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See DTC TABLE [LF, L5].)
(See DTC TABLE [ZY, Z6].)
(See DTC TABLE [MZR-CD 2.2].)
(See DTC TABLE [L3 Turbo].)
|
No
|
Go to the next step.
|
||
2
|
INSPECT BATTERY
• Inspect the battery.
(See BATTERY INSPECTION [LF, L5].)
(See BATTERY INSPECTION [ZY, Z6].)
• Is there any malfunction?
|
Yes
|
Recharge or replace the battery, then go to Step 6.
(See BATTERY RECHARGING [LF, L5].)
(See BATTERY RECHARGING [ZY, Z6].)
|
No
|
Go to the next step.
|
||
3
|
INSPECT GENERATOR
• Inspect the generator.
• Is there any malfunction?
|
Yes
|
Replace the generator, then go to Step 6.
|
No
|
Go to the next step.
|
||
4
|
INSPECT AFS CONTROL MODULE CONNECTOR AND TERMINALS
• Switch the ignition to off.
• Disconnect the negative battery cable.
• Disconnect the AFS control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 6.
|
No
|
Go to the next step.
|
||
5
|
INSPECT POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT OR SHORT TO GROUND
• AFS control module connector is disconnected.
• Reconnect the negative battery cable.
• Switch the ignition to ON.
• Measure the voltage at the following terminal (wiring harness-side):
• Is the voltage B+?
|
Yes
|
Go to the next step.
|
No
|
Inspect the METER 15 A fuse.
If the fuse is melt:
• Repair or replace the wiring harness for a possible short to ground.
• Replace the fuse.
If the fuse is deterioration:
• Replace the fuse.
If the fuse is normal:
• Repair or replace the wiring harness for a possible open circuit.
Go to the next step.
|
||
6
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect the disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC from AFS control module using the M-MDS.
• Switch the ignition to ON.
• Perform the “DTC INSPECTION”.
• Is the same DTC present?
|
Yes
|
Replace the AFS control module, then go to the next step.
|
No
|
Go to the next step.
|
||
7
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|