DTC TABLE [DOSING CONTROL UNIT (SKYACTIV-D 2.2)]
id0102k1801500
DTC No. |
Check engine light |
Master warning indication/master warning light |
Charging system warning indication/charging system warning light |
Engine oil warning indication/engine oil warning light |
Engine oil level warning indication/Engine oil level warning light |
Wrench warning indication |
Diesel particulate filter indication/Diesel particulate filter indicator light |
Glow Indicator Light |
Selective catalytic reduction (SCR) warning light |
Condition |
Fail-safe function |
Drive cycle |
Monitor item |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P0137:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (oxygen concentration) circuit low input
|
—
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P0138:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (oxygen concentration) circuit high input
|
—
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P2002:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor efficiency below threshold
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P202E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
Urea injector circuit range/performance problem
|
×
|
1 or 2
|
CCM
|
C
|
×
|
|
P203A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit problem
|
—
|
1
|
CCM
|
C
|
×
|
|
P203B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor malfunction
|
×
|
1
|
CCM
|
C
|
×
|
|
P203C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit low input
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P203D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor circuit high input
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P203E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor malfunction
|
—
|
2
|
CCM
|
C
|
×
|
|
P2047:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector control circuit problem
|
×
|
1
|
CCM
|
C
|
×
|
|
P2048:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector circuit low input
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P2049:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea injector circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
|
P204F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump performance problem problem
|
×
|
1
|
CCM
|
C
|
×
|
|
P205A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea temperature sensor circuit problem
|
×
|
1
|
CCM
|
C
|
×
|
|
P205B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA tank temperature sensor circuit range/performance
|
×
|
1
|
CCM
|
C
|
×
|
|
P208A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump control circuit malfunction
|
×
|
1
|
CCM
|
C
|
×
|
|
P208B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
UREA pump (pumping side) range/performance problem
|
×
|
1 or 2
|
CCM
|
C
|
×
|
|
P208C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
|
P208D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump control circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20B9:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control circuit malfunction
|
×
|
1
|
CCM
|
C
|
×
|
|
P20BB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20BC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20BD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit problem
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P20BF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20C0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit high input
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P20E8:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump pressure too low
|
×
|
1
|
SCR converter
|
C
|
×
|
|
P20E9:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump pressure too high
|
×
|
1
|
SCR converter
|
C
|
×
|
|
P20EA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SCR relay No.1 malfunction
|
—
|
1
|
CCM
|
C
|
×
|
|
P20EB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SCR relay No.1 malfunction (stuck closed)
|
—
|
1
|
CCM
|
C
|
×
|
|
P20EE:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
SCR converter efficiency below threshold
|
×
|
2
|
CCM
|
C
|
×
|
|
P20FA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Open circuit in UREA pump circuit
|
×
|
1
|
CCM
|
C, O
|
×
|
|
P20FB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump (siphoning side) range/performance problem
|
—
|
2
|
CCM
|
C
|
×
|
|
P20FC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20FD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
UREA pump circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
|
P20FF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit malfunction
|
—
|
1
|
CCM
|
C
|
×
|
|
P214F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control malfunction
|
×
|
1
|
CCM
|
C
|
×
|
|
P21C5:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea level sensor: Detection performance malfunction
|
×
|
2
|
CCM
|
C
|
×
|
|
P21CB:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit power supply voltage low input
|
—
|
1
|
CCM
|
C
|
×
|
|
P21CC:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Dosing control unit power supply voltage high input
|
—
|
1
|
CCM
|
C
|
×
|
|
P21DD:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea tank heater control malfunction
|
×
|
1
|
CCM
|
C
|
×
|
|
P2200:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 control circuit range/performance problem
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P2201:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx sensor No.1 system: Nox concentration malfunction
|
—
|
2
|
Nox sensor No.1
|
C
|
×
|
|
P2202:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (NOx oxygen concentration) circuit low input
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P2203:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 (NOx oxygen concentration) circuit high input
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P2204:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Continuous monitoring of NOx sensor No.1 signal validity
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P2205:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1 heater control circuit range/performance problem
|
—
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P220A:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.1: power supply voltage malfunction
|
×
|
1
|
NOx sensor No.1
|
C
|
×
|
|
P220B:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2: power supply voltage malfunction
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
|
P220E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx Sensor No.1 heater: performance problem
|
×
|
1
|
Nox sensor No.1
|
C
|
×
|
|
P220F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx Sensor No.2 heater: performance problem
|
—
|
2
|
Nox sensor No.2
|
C
|
×
|
|
P221C:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater control circuit low input
|
×
|
1
|
CCM
|
C
|
×
|
|
P221D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
Urea hose heater circuit high input
|
×
|
1
|
CCM
|
C
|
×
|
|
P2270:00
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor (oxygen concentration): lean
|
—
|
2
|
NOx sensor
|
C
|
×
|
|
P2274:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor (oxygen concentration): lean
|
—
|
2
|
NOx sensor
|
C
|
×
|
|
P229E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 control circuit range/performance problem
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
|
P229F:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
NOx sensor No.2 system: Nox concentration malfunction
|
—
|
2
|
Nox sensor No.2
|
C
|
×
|
|
P22A0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor circuit low input
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
|
P22A1:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 circuit high input
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
|
P22A2:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
Continuous monitoring of NOx sensor No.2 signal validity
|
—
|
2
|
Nox sensor No.2
|
C
|
×
|
|
P22A3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
NOx sensor No.2 heater control circuit range/performance problem
|
—
|
1
|
NOx sensor No.2
|
C
|
×
|
|
P24AE:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor control circuit range/performance problem
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P24AF:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor circuit range/performance
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P24B1:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor circuit high input
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P24B3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal heater circuit current low input
|
—
|
1
|
PM sensor
|
C
|
×
|
|
P24B6:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal heater circuit current high input
|
—
|
1
|
PM sensor
|
C
|
×
|
|
P24B7:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor heater resistance malfunction
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P24C6:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal temperature sensor malfunction
|
—
|
1
|
CCM
|
C
|
×
|
|
P24C7:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor temperature circuit range/performance
|
—
|
2
|
PM sensor
|
C
|
×
|
|
P24D0:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
PM sensor: internal supply voltage malfunction
|
—
|
1
|
PM sensor
|
C
|
×
|
|
P24DA:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
ON
|
PM sensor system: Protection tube error
|
—
|
2
|
PM sensor
|
C
|
×
|
|
U0073:00
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN system communication error (HS CAN)
|
×
|
1
|
other
|
C, O
|
×
|
|
U0100:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication: communication error to PCM
|
×
|
1
|
CCM
|
C, O
|
×
|
|
U029D:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: NOx sensor No.1 information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
|
U029E:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: NOx sensor No.2 information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
|
U02A2:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
SENT communication system: UREA quality sensor information communication error with dosing control unit
|
×
|
1
|
CCM
|
C, O
|
×
|
|
U02A3:00
|
ON
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
OFF
|
CAN communication system: PM sensor information communication error with dosing control unit
|
—
|
1
|
CCM
|
C, O
|
×
|